HRV4Training
  • Home
  • QuickStart Guide
  • PRO & TEAMS
  • FAQ
  • Privacy & Terms
  • Contact
  • Publications
  • Guides
  • Blog
  • Shop

Scosche's Rhythm24 & Heart Rate Variability

5/11/2018

 
Blog post by Marco Altini

​Scosche recently announced their latest sensor, the Rhythm24. The new sensor builds on the previous Rhythm+, and adds a lot of new functionalities, including an heart rate variability (HRV) mode. For a detailed overview of the many functionalities of the sensor, check out DC rainmaker's review here. 

In this post, we will focus on only one of the many new features this sensor brings, which is the ability to send accurate RR intervals, which can be used for heart rate variability analysis once connected to an app such as HRV4Training. We've been very happy with a few preliminary tests, and would recommend using this sensor to everyone that had trouble with the camera based measurement (for example on some of the non-compatible Android phones) or simply prefers to rely on an external sensor.

You can get the sensor at this link or clicking below:


If you've been following some of our previous validations, you know that most wristbands, while accurate for heart rate analysis, cannot be used for HRV, as they heavily filter the signal (a procedure typically needed to acquire a more stable signal, less affected by motion artifacts, and therefore able to guarantee a more reliable heart rate during exercise, which is the main target application of such sensors).

​Let's look at some data. 
Picture
Picture
Picture

Data collection

Data was acquired using the rhythm24 sensor and a Polar H7 (previously validated with respect to ECG here), both connected to a different device running the HRV Logger app, which is an app that simply records everything coming from the sensor plus additional features. 

During data acquisition, we collected data a few minutes while breathing freely, and a few minutes while deep breathing, to elicitate higher HRV due to RSA. You will see in the plots below visually the effect of deep breathing as we get greater swings in RR intervals.

A final note on data synchronization: data cannot be perfectly synchronized because it is not timestamped by the sensors. What we can do is either to log real time and then to split data in windows based on when data was collected, then compute HRV features on these windows or to sum up RR intervals over time. For this analysis we went with the second option and also tried to visually align the data streams.
Picture
Picture
Picture
Picture
Picture

RR intervals

We will start by looking at RR intervals, the basic unit we need to compute HRV features. RR intervals (peak to peak differences in consecutive heart beats) are provided by the two sensors directly, so we don't really need to do much to collect them, apart from linking the sensor to the HRV Logger app and export the csv files.

As a third comparison, we will add also an RR intervals time series in which we removed artifacts automatically using the algorithms implemented in HRV4Training. While these recordings were taken at rest, we can see one clear artifact in the second subject's data (minute 2), and its effect on HRV features in the next section. Using this simple artifact removal, we can get easily the proper HRV values.
​
Picture
Let's look at data from another person. Here in the second row, second column, we can see an artifact, which does not appear in the first row (Polar data). However, we can also see how applying the artifact removal filter, the artifact disappears (third row, filtered Rhythm24 data).
Picture

​What can we derive from these data? You can see clearly  almost perfect correlation between Polar H7 and Rhythm24 for all conditions (relaxed vs paced breathing as highlighted by bigger oscillations in RR intervals or instantaneous heart rate), meaning that the sensor works really well in this modality.

Heart rate variability: rMSSD

​As features, we will look only at rMSSD, the only feature we really care about. rMSSD is a clear marker of parasympathetic activity and the main feature we use for our analysis in HRV4Training, similarly to what other apps do as well. Additionally, the sports science community seems to have settled on this feature for several reasons (practical as well as it is easy to acquire, compute and reliable over short time windows and less controlled conditions), and therefore we'll stick to it.

What we expect given the data above is to see extremely close values between the Polar H7 chest strap and Rhythm24 data.

For the plot below, I computed rMSSD for each time window and subject:
Picture
Results are very good considering normal variation in physiology and limitations in data synchronization. However, it is certainly paramount to take care of artifacts, as we can see again in subject 002, second minute of data.

Movement and artifacts

As a final experiment, we tried to add a little movement to the measurement. Nothing crazy, just computer work, a little muscle contraction, etc. If you've been using HRV4Training, you have certainly noticed how it is key not to move while using the camera based measurement, as movement introduces a lot of artifacts. The same applies to the Rhythm24, as it is simply not possible to use optical technologies during movement, when looking at HRV analysis. 

Below is an example of two minutes of RR intervals while performing some of the movements mentioned above, and also the resulting very high HRV, which is simply due to artifacts:
Picture
Below we can see the effect of the artifacts on rMSSD:
Picture
While the artifact correction can recover decently the  second minute of data, there were too many artifacts in the first minute. In general, we would recommend staying completely still while measuring, which should be no problem for your morning measurement of chronic stress.

Make sure also to use an app that reports signal quality, so that you will know if something went wrong, and can measure again in that case. HRV4Training will report back to you signal quality after each measurement, based on how many artifacts were found during the recording.  We recommend keeping always only measurements labeled as Optimal by the app. Note that it is impossible for a user to understand if artifacts were present when using an app that computes HRV without reporting signal quality, hence the need to avoid using such apps, as artifacts sometimes are simply not avoidable. Real life is messy, we should design for it.

Summary and other useful resources

That's all for this post. We are very pleased to see more and more sensors manufacturers spending time to work on 'HRV modalities' in which accurate RR intervals are sent via standard protocols, and hope that more will come in the future, making it easier for users to gather reliable data. Scosche did great work on the Rhythm24, as shown in the plots reported in this blog post. However, always pay attention to data quality and artifacts, as movement highly affects optical measurements. Some additional resources:
  • Comparison of other PPG sensors
  • Normal variation in repeated measures in physiology
  • A discussion on paced breathing and HRV analysis
  • Apple Watch and HRV

Comments are closed.
    Picture
    Picture
    Register to the mailing list
    and try the HRV4Training app!
    Picture
    Picture
    This blog is curated by
    Marco Altini, founder of HRV4Training


    ​Blog Index
    ​
    The Ultimate Guide to HRV
    1: Measurement setup
    2: Interpreting your data
    3: Case studies and practical examples

    How To
    1. Intro to HRV
    ​2. How to use HRV, the basics
    3. HRV guided training
    ​4. HRV and training load
    ​
    5. HRV, strength & power
    6. Overview in HRV4Training Pro​
    7. HRV in team sports
    ​

    HRV Measurements
    Best Practices

    1. Context & Time of the Day
    2. Duration
    ​
    3. Paced breathing
    4. Orthostatic Test
    5. Slides HRV overview
    6. Normal values and historical data
    ​7. HRV features
    ​
    Data Analysis
    1a. Acute Changes in HRV
    (individual level)

    1b. Acute Changes in HRV (population level)
    ​
    1c. Acute Changes in HRV & measurement consistency
    1d. Acute Changes in HRV in endurance and power sports​
    2a. Interpreting HRV Trends
    2​b. HRV Baseline Trends & CV
    3. ​Tags & Correlations​
    4. Ectopic beats & motion artifacts
    5. HRV4Training Insights
    6. HRV4Training & Sports Science
    7. HRV & fitness / training load
    ​8. HRV & performance
    9. VO2max models
    10. Repeated HRV measurements
    11. VO2max and performance
    12. HR, HRV and performance
    13. Training intensity & performance​
    14. Publication: VO2max & running performance
    ​
    15. Estimating running performance
    16. Coefficient of Variation
    17. More on CV and the big picture
    ​​​​​18. Case study marathon training
    19. Case study injury and lifestyle stress
    20. HRV and menstrual cycle
    21. Cardiac decoupling
    22. FTP, lactate threshold, half and full marathon time estimates
    ​23. Training Monotony
    ​
    Camera & Sensors
    1. ECG vs Polar & Mio Alpha
    2a. Camera vs Polar
    2b. Camera vs Polar iOS10
    2c. iPhone 7+ vs Polar
    2d. Comparison of PPG sensors
    3. Camera measurement guidelines
    4. Validation paper
    ​5. Android camera vs Chest strap
    ​6. Scosche Rhythm24
    ​7. Apple Watch
    8. CorSense
    ​
    9. Samsung Galaxy
    ​
    App Features
    ​1. Features and Recovery Points
    2. Daily advice
    3. HRV4Training insights
    4. Sleep tracking
    5. Training load analysis
    ​6a. Integration with Strava
    6b. Integration with TrainingPeaks
    6c. Integration with SportTracks
    6d. Integration with Genetrainer
    ​
    6e. Integration with Apple Health
    ​
    ​6f. Integration with Todays Plan
    7. Acute HRV changes by sport
    8. Remote tags in HRV4T Coach
    9. VO2max Estimation
    ​
    10. Acute stressors analysis
    11. Training Polarization
    ​
    12. Lactate Threshold Estimation
    13. Functional Threshold Power(FTP) Estimation for cyclists
    14. Aerobic Endurance analysis
    15. Intervals Analysis
    ​​​16. Training Planning
    17. Integration with Oura
    18. Aerobic efficiency and cardiac decoupling
    ​
    Other
    1. HRV normal values​
    ​2. HRV normalization by HR
    ​
    3. HRV 101

    RSS Feed

Picture
  • Home
  • QuickStart Guide
  • PRO & TEAMS
  • FAQ
  • Privacy & Terms
  • Contact
  • Publications
  • Guides
  • Blog
  • Shop